Cleanroom Contractor in Batam, Indonesia
Cleanroom Contractor. Built for Batam's Industry.
ISO Class 5–8 cleanroom design and construction for semiconductor, pharmaceutical, and medical device facilities across Batam — engineered for contamination control, airflow precision, and GMP compliance.



World-Class Cleanroom Services
Turnkey ISO Class 5–8 cleanroom construction for semiconductor, pharmaceutical, and precision manufacturing facilities in Batam, Indonesia. From design and MEP integration through validation and handover — one team, one point of accountability, audit-ready from day one.



ISO-class Cleanroom Systems
- ISO Class 5–8 cleanrooms for semiconductor, pharmaceutical, and medical device facilities
- Modular 50/75 mm panels, walkable grids, interlocked sealed doors, and anti-static raised flooring
- Engineered pressure cascades — ±5 Pa typical, ±15 Pa for biocontainment zones
- ISO 14644 commissioning: particle count, recovery, airflow visualisation, HEPA/ULPA leak testing
- IQ/OQ/PQ validation packages for GMP and 21 CFR Part 11 audits
HVAC & Airflow Systems
- AHUs with H13/H14 HEPA and U15 ULPA filtration via ceiling plenum or terminal distribution
- Air change rates from 20 ACH (ISO 8) up to 240 ACH (ISO 5)
- Load sizing for occupancy, internal heat, process exhaust, and recovery time
- BMS monitoring of temperature, humidity, differential pressure, and live particle counts
- GMP-grade trend logs for batch traceability and root-cause analysis
Construction & Design
- Modular 50/75 mm wall and ceiling panels with anti-static raised access flooring
- Seamless self-levelling epoxy with integral coving and sealed cleanroom electrical
- Flush-mount stainless fittings, interlocked gowning rooms, and pass-through chambers
- Low-outgassing materials, chemically compatible with your process media
- Phased construction for live-facility upgrades — adjacent lines keep running
ISO-class Cleanroom Systems
ISO Class 5–8 cleanrooms for semiconductor, pharmaceutical, and medical device facilities
Modular 50/75 mm panels, walkable grids, interlocked sealed doors, and anti-static raised flooring
Engineered pressure cascades — ±5 Pa typical, ±15 Pa for biocontainment zones
ISO 14644 commissioning: particle count, recovery, airflow visualisation, HEPA/ULPA leak testing
IQ/OQ/PQ validation packages for GMP and 21 CFR Part 11 audits
HVAC & Airflow Systems
AHUs with H13/H14 HEPA and U15 ULPA filtration via ceiling plenum or terminal distribution
Air change rates from 20 ACH (ISO 8) up to 240 ACH (ISO 5)
Load sizing for occupancy, internal heat, process exhaust, and recovery time
BMS monitoring of temperature, humidity, differential pressure, and live particle counts
GMP-grade trend logs for batch traceability and root-cause analysis
Construction & Design
Modular 50/75 mm wall and ceiling panels with anti-static raised access flooring
Seamless self-levelling epoxy with integral coving and sealed cleanroom electrical
Flush-mount stainless fittings, interlocked gowning rooms, and pass-through chambers
Low-outgassing materials, chemically compatible with your process media
Phased construction for live-facility upgrades — adjacent lines keep running
Proven for International Manufacturing Standards
Delivering cleanroom projects in Batam, Indonesia for international manufacturers operating under strict performance and compliance requirements. Our completed facilities serve active production lines in semiconductor fabrication, medical device assembly, and pharmaceutical manufacturing.
Clients rely on our disciplined methodology, structured documentation control, and schedule-driven project delivery.






From Shell to Validation.
From production expansions to new ISO Class 5–8 facilities, our team scopes the build from architectural shell through validation and operational handover. Share your URS, layout sketches, or operating constraints — we'll come back with a phased construction plan, validation strategy, and milestone-based timeline.
Send Your Brief






Epoxy-Floored Cleanroom Facility
Seamless, anti-static epoxy flooring integrated within a controlled cleanroom environment — designed for durability, easy maintenance, and strict contamination control.
Epoxy-Floored Cleanroom Facility
Seamless, anti-static epoxy flooring integrated within a controlled cleanroom environment — designed for durability, easy maintenance, and strict contamination control.
Engineered for Electrostatic Control
Anti-static raised floor cleanroom built to minimise electrostatic discharge and maintain strict contamination control for high-precision manufacturing environments.
World-Class HVAC Plenum System
Engineered plenum and air distribution system designed for uniform airflow, pressure stability, and precise environmental control in cleanroom environments.
Air Handling Unit Installation
Engineered AHU installation delivering controlled airflow, temperature regulation, and stable environmental performance for cleanroom and industrial applications.
Air Handling Unit Room
Dedicated AHU room designed for controlled air distribution, system accessibility, and stable environmental performance within cleanroom and industrial facilities.
Cold Storage Room
Temperature-controlled cold storage facility engineered for consistent cooling performance, insulation efficiency, and reliable environmental stability in regulated industrial environments.
Cleanroom Compressed Air System
Oil-free, contaminant-controlled compressed air system engineered for cleanroom environments — ensuring stable pressure, air purity, and compliance with critical manufacturing standards.